Aluminium Doors · Australia

AS 2047-certified aluminium doors for Australian projects

Sliding, triple-track, ultra-slim and casement aluminium doors — including thermally broken (broken-bridge) systems — engineered, tested and documented to Australian Standards for builders, architects, specifiers and importers.

AS 2047:2014Windows & external doors
AS/NZS 1170.2Wind load actions
Thermally brokenBroken-bridge systems available

Door styles

Each style is available across multiple aluminium series, including thermally broken (broken-bridge) systems engineered for the Australian market.

Sliding

Sliding & triple-track doors

Single, dual-rail and triple-track sliding doors with integrated screen tracks for wide openings and seamless indoor–outdoor transitions.

100 / 105 / 137 / 150 / 160 / AUS 200 / 207 Series
Ultra-slim

Ultra-slim sliding doors

Minimal sightline triple-track systems that maximise glass and views for premium residential and feature openings.

40 Series Ultra-Slim Triple-Track
Casement

Casement & hinged doors

Side-hinged casement doors with high weather-tightness, available with screens and in thermally broken systems for exposed and energy-rated projects.

K120 / AUS 100 / K65 Series
Thermally broken

Thermally broken doors

Broken-bridge sliding and casement systems with polyamide thermal breaks to support lower U-values and NCC energy compliance.

100 / 137 / 150 / AUS 200 / K120 / K65 Series

Standard sizes (Australia)

Common nominal opening sizes specified across Australian residential and commercial projects. Seamless manufactures to project dimensions, so units are made to order around your schedule rather than a fixed catalogue.

Door styleTypical widthTypical heightNotes
Sliding door (2-panel)1500 – 3600 mm2000 – 2400 mmOne fixed, one sliding panel; wider openings use additional tracks.
Triple-track sliding door2400 – 5400 mm2000 – 2700 mmStacking panels for expansive openings with integrated screen track.
Casement / hinged door700 – 1000 mm per leaf2000 – 2400 mmSingle or double leaf; mulled with side and highlight glazing.
Ultra-slim sliding door1800 – 4800 mm2100 – 2700 mmMinimal sightlines maximise glass area and views.

Sizes shown are typical nominal ranges for reference only. Confirm exact dimensions, wind-pressure ratings and glazing for your project with our technical team.

Thermal & weather performance

Engineered for Australian conditions

From wind-exposed coastal sites to climate-zone energy targets, Seamless aluminium systems are built to perform — and documented so you can prove it.

Broken-bridgePolyamide thermal break isolates inside from outside
Double glazingSealed IGUs to AS/NZS 4666 on thermally broken series
AS/NZS 1170.2Wind-pressure rated by series and wind region
AS 1288Glazing selected for impact safety & structural loads
  • Thermally broken frames reduce conductive heat transfer, supporting lower U-values for NCC energy compliance.
  • Multi-point locking and quality weather seals improve water-penetration resistance and air-tightness.
  • U-value and SHGC data is issued per series to feed directly into your energy assessment.

Compliance & standards

The Australian Standards every Seamless door is engineered and documented against — ready to hand to your certifier.

StandardWhat it governsApplies toDocs available
AS 2047:2014Windows & external glazed doors in buildingsMaterials, construction, water penetration resistance, structural performance and operation of windows and external doors.All residential & commercial window and door supply
AS 1288Glass in buildings — selection & installationHuman impact safety, wind, and structural glazing requirements governing the glass specified in each unit.Glazing selection for every project
AS/NZS 1170.2Structural design actions — wind actionsWind load assumptions used to rate products by serviceability and ultimate limit-state pressures for a given wind region.Wind region & exposure rating
AS/NZS 4666Insulating glass unitsPerformance and durability requirements for double-glazed (IGU) sealed units used in thermally broken systems.Thermally broken / double-glazed series
NCC / BCA energy efficiencyNational Construction Code thermal performanceU-value and SHGC inputs required to demonstrate a project meets the energy efficiency provisions of the NCC.Energy compliance documentation

Product-specific test certificates, wind-pressure ratings and energy values are issued per series — request the documents below or contact our technical team.

Door specification FAQ

Common questions from builders, architects and specifiers sourcing aluminium doors.

Are your aluminium doors certified to AS 2047:2014?+

Yes. External doors supplied to the Australian market are engineered and tested to AS 2047:2014, with structural, water-penetration and operating-force test reports issued per series on request.

What door styles do you manufacture?+

Sliding doors (single, dual-rail and triple-track with screens), ultra-slim sliding doors, and casement/hinged doors — available in standard and thermally broken (broken-bridge) aluminium series.

What are the standard door sizes in Australia?+

Sliding doors commonly span from around 1500mm to 5400mm wide at 2000mm to 2700mm high depending on configuration. Seamless manufactures to project dimensions, so doors are made to order rather than to a fixed catalogue.

Can you supply doors with integrated screens?+

Yes. Triple-track sliding doors include a dedicated screen track, and screen options are available across the casement and sliding ranges.

Do thermally broken doors help with energy compliance?+

A polyamide thermal break reduces conductive heat transfer through the frame, supporting lower U-values. U-value and SHGC data is available per series to feed into your NCC energy assessment.

Specifying doors for a project?

Send us your door schedule, sizes and wind region. Our technical team will return a quote with the right series, glazing and compliance documentation for your project.